Background: Ultrasound of the optic nerve sheath diameter (ONSD) has been used as a non-invasive and cost-effective bedside alternative to invasive intracranial pressure (ICP) monitoring. However, ONSD time-lapse behavior in intracranial hypertension (ICH) and its relief by means of either saline infusion or surgery are still unknown. The objective of this study was to correlate intracranial pressure (ICP) and ultrasonography of the optic nerve sheath (ONS) in an experimental animal model of ICH and determine the interval needed for ONSD to return to baseline levels. Methods: An experimental study was conducted on 30 pigs. ONSD was evaluated by ultrasound at different ICPs generated by intracranial balloon inflation, saline infusion, and balloon deflation, and measured using an intraventricular catheter. Results: All variables obtained by ONS ultrasonography such as left, right, and average ONSD (AON) were statistically significant to estimate the ICP value. ONSD changed immediately after balloon inflation and returned to baseline after an average delay of 30 min after balloon deflation (p = 0.016). No statistical significance was observed in the ICP and ONSD values with hypertonic saline infusion. In this swine model, ICP and ONSD showed linear correlation and ICP could be estimated using the formula: -80.5 + 238.2 × AON. Conclusion: In the present study, ultrasound to measure ONSD showed a linear correlation with ICP, although a short delay in returning to baseline levels was observed in the case of sudden ICH relief. © 2021 Elsevier Ltd

Copyright © 2021 Elsevier Ltd. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0967-5868, 1532-2653

Journal Of Clinical Neuroscience  Churchill Livingstone

Tipo:
Article
Páginas:
174-179
PubMed:
33775322
Enlace a otro recurso:
www.scopus.com

Citas Recibidas en Web of Science: 7

Citas Recibidas en Scopus: 15

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Animals; Disease Models, Animal; Intracranial Hypertension; Intracranial Pressure; Monitoring, Physiologic; Optic Nerve; Prospective Studies; Swine; Ultrasonography; sodium chloride; Article; brain hematoma; clinical feature; controlled study; echography; intracranial hypertension; intracranial pressure; nonhuman; optic nerve; optic nerve sheath diameter; pig; priority journal; animal; diagnostic imaging; disease model; echography; intracranial hypertension; intracranial pressure; optic nerve; pathophysiology; physiologic monitoring; physiology; procedures; prospective study

Citar la publicación

Compartir la publicación